_images/BuildingDepot.svg

Central Service

The Central Service within BuildingDepot is the part of the system that holds all the core metadata. Starting from the structures of the Buildings to the DataServices that lie in an installation the CentralService plays a very important role in organising the data within BuildingDepot in a meaningful way. A brief explanation will be provided here of each of the options available in the CentralService.

We define any entity to which a timeseries can be associated with as a Point. A Point can be measurements from sensors, or commands to turn a light on/off, or a configuration parameter such as cycle type in a washing machine or even a fault indicator. This includes both real­world sensors/actuators, as well as virtual sensors/actuators created in the Central Service as abstractions of RealWorld sensors/actuators (such as a ‘building average temperature sensor’). Virtual and RealWorld points are treated identically within the CentralService, with differences occurring at the level of connectors (see Connectors document for interfacing between the CentralService and sensors). In BuildingDepot, each point is given a UUID (universally unique ID) and metadata is associated with it using tags.

Tags are key value pairs associated with a point. For example, an office temperature sensor would be associated with tags like “Room = 300”, “Type = Temperature Sensor”, “Unit = Fahrenheit” and so on. Tags themselves can refer to complex entities and be associated with other tags. For example, Room 300 can be associated with its metadata such as area and usage type . Tags form the core of BuildingDepot metadata, and are used for searching and defining permissions.

BuildingDepot supports pre­defined tag types that acts as a template for a user to start tagging entities in a building. These templates are provided to support standard naming convention, such as the tags defined by Project Haystack2. These tags are also used as the key search mechanism within BuildingDepot. Using REST APIs, users can query for individual entities based on single tag (such as a Room = 300) or based on more complex combinations of tags (Room = 300 and Type = Occupancy and Building = Example_Building). All entities which meet the requirements of the search are returned as JSON objects which contain their UUID, tags, and Metadata. In addition to tags on entities, BuildingDepot also utilizes context based tags for Users. Depending on how a user logs in (e.g. with or without admin privileges) they will have a context tag added to determine the privileges that they enjoy (user credentials). Users groups are created by assigning a user­group tag to each user which is part of the group. This is of particular importance later when determining permissions.

In addition to User Groups, Sensor groups are as the name suggests a set of points that have been grouped together on the basis of the tags that the user selected while creating the group. While creating a Sensor group each individual points that the user wants to put in the group do not have to be manually added. Simply selecting the tag will automatically add at the backend all the points containing that tag into this group. Sensor groups and User groups come together to form the access control lists. Access control lists are a key element in BuildingDepot to facilitate both privacy and security. For pairs of User Groups and Sensor Groups, we choose a permission value with which we want to associate. There are four levels of permission defined in BuildingDepot which are ‘d/r’ (deny read) ,’r’ (read) , ‘r/w’ (read write) and ‘r/w/p’ (read write permission). If there are multiple permission mappings between a user and a point then the one that is most restrictive is chosen. The deny read permission level, in particular, is important for maintaining privacy of data for various groups simultaneously using BuildingDepot for a building.

Different evels of permission access:
  • d/r: Deny/Read will deny any access to the points

  • r: Read will give read only access to the points

  • r/w: Read/Write will give read and write access to the points (such as changing values of actuators)

  • r/w/p: Read/Write/Permission is the highest level of permission that can be assigned. Will give read and write access to the points. This permission also allows users to alter permissions for the points (see above).

Note:
  • The ownership level of permission is assigned at the point of creation. It has all privileges of r/w/p. Additionally, it cannot be revoked or changed under any circumstances.

  • The super users of BuildingDepot have r/w/p access to all the points.

When a r/w/p permission link is created between the UserGroup “Home_usergroup” and Sensor Group “Home”. All users in UserGroup get r/w/p access to points in SensorGroup. Any user can create any permission link that they want but the set of points that the users in the UserGroup get access to in the SensorGroup that they have been given permission to will depend on the user that has created the permission. Only the points that the creator of this permission has r/w/p access to will be the points that the users will gain access to based on this permission link.

_images/CSComponents.svg

OAuth

To generate an OAuth token a client id and client secret key are required. These are generated within the DataService by the user through the GUI. These values will be valid until the user regenerates them for that certain account. The process to generate an OAuth token after these values have been obtained is defined in the REST API Documentation.

TagType

Tags are an integral part of BuildingDepot and play an important role in organising and categorising the sensors and their data. Users can create new tags here which will be used in various places throughout BuildingDepot. When creating each tag parent tag(s) can be specified for each tag enabling us to create a tag hierarchy that proves to be very useful when defining structures such as Buildings. Here only the tag names are specified and the values for these tags are specified later on. Each tag can have multiple values if needed.

BuildingTemplate

Each building within BuildingDepot has a BuildingTemplate as a foundation. The BuildingTemplate helps define the structure of the building. The user has to assign a set of tags to the BuildingTemplate on creation which can be used later on for all the sensors within that building.

Building

All the buildings that are present within the deployment of BuildingDepot are defined here. When adding a new building a BuildingTemplate has to be selected which defines the structure of this building. The tags that are available to be assigned to this building are dependent on the BuildingTemplate. Tags can be selected and the values for each of them can be specified here. Each tag can have multiple values specified for it.

Data Services

BuildingDepot consists of a single CentralService and if needed multiple DataServices. The number of DataServices to deploy is a decision that is completely left to the user. A DataService per building is an ideal choice that we suggest. Each DataService has to be specified within the DataService’s section in the CentralService. For each DataService all the buildings that belong to it also have to be selected and added. The admins for each DataService who will have complete administrative control over this DataService also have to be specified here.

Note: The first DataService has to be called “ds1”.

Sensor

Individual sensor points are defined here. After adding a sensor a UUID is generated which will be the unique identifier used in all further transactions with BuildingDepot whether it be reading a datapoint from a sensor or posting a bunch of datapoints to a sensor. Each sensor can also have a set of tags attached to it that not only help in categorising them in a meaningful way but also are critical for defining the access control lists later on. The option to attach metadata that is specific to this sensor is also provided. Sensors can be searched for using either the tags or metadata as a filter.

Sensor Group

Sensor groups are as the name suggests a set of sensors that have been grouped together on the basis of the tags that the user selected while creating the group. While creating a Sensor groups each individual sensor that the user wants to put in the group do not have to be manual added. Simply selecting the tag will automatically add at the backend all the sensors containing that tag into this group.

User Group

Similar to Sensor groups, User groups are a list of users that have been categorised into one group. Groups are created using the user email id that was used during registration.

Permission

In the permissions section Sensor groups and User groups come together to form the access control lists. Here we select a User Group and a Sensor Group and a permission value with which we want to associate these both. There are three levels of permission defined in BuildingDepot which are ‘d/r’ (deny read) ,’r’ (read), ‘r/w’ (read write) and ‘r/w/p’ (read write permission). If there are multiple permission mappings between a user and a sensor then the one that is most restrictive is chosen.